您好, 歡迎來(lái)到化工儀器網(wǎng)! 登錄| 免費(fèi)注冊(cè)| 產(chǎn)品展廳| 收藏商鋪|
當(dāng)前位置:上海境宣實(shí)業(yè)有限公司>>日本光明北川式氣體檢測(cè)管>>氣體快速檢測(cè)管>> 105SD戊胺CH3(CH2)3CH2NH2氣體檢測(cè)管105SD PENTYL AMINE 2-22ppm
參 考 價(jià) | 面議 |
產(chǎn)品型號(hào)105SD
品 牌
廠(chǎng)商性質(zhì)代理商
所 在 地上海市
更新時(shí)間:2025-03-11 10:11:00瀏覽次數(shù):1638次
聯(lián)系我時(shí),請(qǐng)告知來(lái)自 化工儀器網(wǎng)苯氣體檢測(cè)管118SB BENZENE 5-300ppm
室內(nèi)空氣甲醛檢測(cè)管No.713 FORMALDEHYDE 0.01-0
氯乙烯CH2=CHCl氣體測(cè)毒管132SC VINYL CHLORID
氯乙烯CH2=CHCl氣體檢知管132SB VINYL CHLORID
戊胺CH3(CH2)3CH2NH2氣體檢測(cè)管105SD PENTYL AMINE 2-22ppm
Tube 05SD
1. PERFORMANCE
1) Measuring range :1-20 ppm 0.2-1 ppm
Number of pump strokes 1(100ml) 5(500ml)
2) Sampling time :1 minute/1 pump stroke
3) Detectable limit :0.1 ppm(100ml)
4) Shelf life :3 years
5) Operating temperature :0~40℃
6) Reading :Direct reading from the scale calibrated by 1 pump stroke
7) Colour change :Pale purple→Pale Yellow
2. RELATIVE STANDARD DEVIATION
RSD-low:10% RSD-mid.:5% RSD-high:5%
3. CHEMICAL REACTION
By reacting with Phosphoric acid, PH indicator is discoloured.
2NH3+H3PO4→(NH4)2PO4
4. CALIBRATION OF THE TUBE
PERMEATION TUBE METHOD
5. INTERFERENCE AND CROSS SENSITIVITY
20
18
16
14
12
10
8
6
4
2 1
100ml
ppm
GAS To pump
DEHUMIDIFIER
(White)
105SD AMMONIA
Substance Interference Coexistence
Amines Similar stain is produced. Higher readings are given.
(NOTE)
When the concentration is below 1 ppm, 2 to 5 pump strokes can be used to detemine the lower concentration.
Following formula is available for actual concentration.
Actual concentration=Reading value× 1
Number of strokes
The KITAGAWA Gas Detector Tube System is a complete sampling and analysis system for determining hazardous gas and vapour concentrations quickly and easily. The KITAGAWA Gas Detector Tube System is comprised of an Air Sampling Pump and Precision Gas Detector Tubes.
The KITAGAWA air sampling pump reproducibly draws 100cc of sample air through the detector tube. All detector tubes are calibrated for a single pump stroke; there is no need for multiple volumes or stroke counters.
Each detector tube is formulated with high purity reagents that absorb and react with the target gas or vapour being measured. A colorimetric stain is created that is proportional in length to the concentration. For most tubes, the concentration is read directly off the measurement scale on each tube.
How To Use The KITAGAWA Gas Detector Tube System
Detector tubes are available to measure more than 200 different kinds of gases and vapours. For many gases and vapours, there are several concentration ranges available giving you the flexibility to measure both low and high concentrations without sacrificing precision.
For specific information, please refer to the list of detector tubes.